Thank you for buying WH Series high-power induction heating equipment.
In order to use the power supply correctly and prevent the hidden and unexpected accident in the future, please read the instruction carefully before installation and operation, and keep it properly for reference.
I. Preparation before installation. 2
II.Method of Installation. 5
III.Turn on and Operation. 7
IV.Operation Precautions. 7
V.Troubles and Settlements. 8
VI.Technical Parameters. 9
VII.Circuit Principle Frame. 10
VIII.Packing List of Equipment 10
I. Preparation before installation
1. Learn the Panel Function
These series equipment have two types according to frame---holistic type and separate type. There are many models according to different power for each kind. Please remember the relative panel functions by heart according to the frame and power model.
Items in the picture WH-VI-16:
WH-VI-16 微型高频感应加热电源---WH-VI-16 mini-type high frequency induction heating power
功率调节---power control 减---reduce 增---increase 加热---heating 停止---stop 远控---remote control 开关---on and off 电源---power supply 加热---heating 电压---voltage 水压---hydraulic pressure 电流---current 水温---water temperature
Items in the picture WH-VI-26:
WH-VI-26 微型高频感应加热电源---WH-VI-26 mini-type high frequency induction heating power
功率调节---power control 减---reduce 增---increase 水温---water temperature水压---hydraulic pressure过流---over-current 过压---over-voltage 工作---work 电源---power supply远控---remote control 加热---heating 停止---stop 开关---on and off
Items in the picture WH-VIII-30BE:
高频感应加热设备--- high frequency induction heating equipment
振荡电流--- oscillating current 电源电压---power and voltage 缺相---open-phase水温---water temperature水压---hydraulic pressure过流---over-current 过压---over-voltage 工作---work 电源---power supply 电源开关---power switch 过流复位--- over-current restoration 手动自动---manual or automatic功率调节---power control 减---reduce 增---increase加热停止---heating and stop 远控---remote control 时间控制---time control 定时复位--- timing restoration
Items in the picture WH-VIII-50BE WH-VIII-80BE WH-VIII-120BE:
高频感应加热电源---high frequency induction heating power
缺相---open-phase水温---water temperature水压---hydraulic pressure过流---over-current 过压---over-voltage 工作---work 电源---power supply 功率调节---power control 减---reduce 增---increase远控---remote control 加热停止---heating and stop过流复位--- over-current restoration 控制开关---control switch
Name |
Function |
Display meter of power and voltage |
Display the volts direct current. |
Display meter of oscillating current |
Under heating conditions it will fluctuate between 0-800. Under the stop condition, it shows “0”. It shows the trend of power is high or low, increased or decreased. |
Power control button |
Under heating condition adjust this button can accommodate the power to reach your requirement for heating temperature and speed. |
Alarm indicator lamp for water temperature |
If this indicator lamp is on parts is too hot and water temperature is too high. |
Alarm indicator lamp for hydraulic pressure |
When the water pressure of the cooling water is too low or lacks water, this indicator lamp will be on. |
Alarm indicator lamp for over-current |
When this indicator lamp is on the temperature is too high and Inter-turn short circuit occurs in the inductor. Please turn off the equipment and examine it immediately. |
Alarm indicator lamp for over-voltage |
When this indicator lamp is on the supply voltage exceeds the regulated range. |
Heating and stop button |
Press it to heat and loosen it to stop. |
remote control |
It is used to connect the remote control switch or foot switch to achieve remote control. |
Over-current restoration |
Release from the over current condition. |
Power supply switch |
This switch is the control power supply switch. Press it to switch on and loosen to switch off. |
Manual and automatic |
Turn on this switch can transform the manual or automatic condition. |
Time control |
Set the heating time(WH-30). |
Time restoration |
Press it to start timing again(WH-30). |
Panel Function Table
2. Power supply requirement and wiring
Range of input voltage:
16KW-----single-phase: 180-240V
26KW, 50KW, 80KW, 120KW, 160KW, 260KW-----three-phase four-wire system: 320-420V
Don’t connect in wrong way for of causing damaging to the equipment. While mains voltage exceeds limit, please don’t turn on the equipment.
Wire: These series products are of equipment with high power, so please ensure enough wire and reliable wiring to prevent the connection point from generating severe heat due to high contact resistance and joint current. Please choose specification of power cord referring to the following table 1. The power cord is a kind of copper core with withstands voltage 500V.
Table 1
Model |
WH-VI-16 |
WH-VI-26 |
WH-VIII-40 |
WH-VI-50 |
WH-VIII-80 |
WH-VIII-120 |
WH-VIII-160 |
WH-B-260 |
spec. of wire under voltage mm2 |
10 |
10 |
16 |
16 |
25 |
50 |
50 |
80 |
spec. of null line mm2 |
6 |
6 |
10 |
10 |
10 |
10 |
10 |
10 |
air-break switch |
60A |
60A |
100A |
100A |
160A |
200A |
300A |
500A |
² The equipment must be reliable earth connection according to the requirement. The frame must be reliable protective bonding to neutral. It is strictly prohibited to connect the ground wire with the water supply pipe.
² The line must be setting by the professional person according to the nation wiring rules. The power supply final stage must install relative air-break switch.
² Please shut off the power cord when you don’t use the equipment.
3. Requirement for cooling water
The inner of equipment and inductor must be cooled down with clean water to prevent the cooling pipe from blocking. If the equipment supplies water with pump, please install filter screen at pump intake. Temperature of cooling water shall not be higher than 45℃ or it will lead to equipment alarm even overheating damage. Please see table 2 for detailed requirement.
Table 2
Model |
self-sucking pump |
Pipe diameter of required water hose (inner)mm |
Pull volume (no less than)m3 |
|
Water pump power KW |
lift/press(m/MPa) |
|||
WH-VI-16 |
0.55 |
20-25/0.2-0.3 |
10 |
3 |
WH-VI-26 |
0.55 |
20-25/0.2-0.3 |
10,25 |
4 |
WH-VIII-40 |
0.75 |
20-25/0.2-0.3 |
25 |
6 |
WH-VI-50 |
0.75 |
20-25/0.2-0.3 |
25 |
6 |
WH-VIII-80 |
1.1(three-phase) |
20-25/0.2-0.3 |
25,32 |
10 |
WH-VIII-120 |
1.1(three-phase) |
20-25/0.2-0.3 |
25,32 |
15 |
WH-VIII-160 |
1.1(three-phase) |
20-25/0.2-0.3 |
25,32 |
15 |
WH-B-260 |
2.2(three-phase) |
20-25/0.2-0.3 |
50,64 |
30 |
Inlet water temperature |
Water quality |
Hardness |
Conductivity |
Inlet water pressure |
5-35℃ |
PH 7-8.5 |
No more than 60mg/L |
Less than 500µA/cm3 |
1×105-3×105Pa |
II.Method of Installation
Please install according to obvious marks on both sides of the panel. Please install according to the following sketch map if you have any problem.
一体式:16KW、26KW、50KW安装示意图(2)
|
(1) 16KW 安装示意图:16 KW installation sketch map
(2) 一体式:16KW、26KW、50KW安装示意图:
Holistic type: 16KW, 26KW, 50 KW installation sketch map
(3)分体式: 80KW、120KW、160KW、260KW安装示意图
Separate type: 80KW, 120KW, 160KW, 260 KW installation sketch map
1.感应器 inductor 2. 进水water inlet 出水water outlet 3. 接地connect to earth 4. 遥控开关/远控接口remote control interface 5.变压器 transformer
单相220V 50-60Hz: single-phase 220V 50-60Hz 三相 380V: Three-phase 380V
WH系列高频 WH Series high frequency 接漏电断路器:connect the residual current circuit breaker
1. Installation of inductor: For holistic type the inductor connect with secondary joint of main control tank directly; for separate please connect the inductor with transformer well and guarantee good contact. The interface of the transformer and inductor should have no water leakage.
2. Connection of cooling water: The inlet and outlet pipe should be connected reliably according to the tablet indication on the engine case. Please make sure that there are no wrong connection, aleak phenomena and seeper in chassis. Please do not sprinkle water into chassis. If it happens please cut off the power supply and drying it.
3. Connect to earth: The frame must be reliable protective bonding to neutral with more than 6mm2 copper wires for three-phase four-line system. It should comply with the standard of electric work.
4. Please connect feet switch with the interface of remote control switch.
5. For separate type induction heating equipment please connect the main control tank with the transformer as the line number accordingly. Please connect the induction coil joint with the transformer secondary joint.
III.Turn on and Operation
1. Please choose appropriate induction coil according workpiece heated.
2. Turn on cooling water, examine flux and press of water to make sure them achieve required area.
3. Turn on the power supply. It is single-phase 220V 50-60Hz for 16KW type and three-phase 380V 50-60Hz for others.
A Open the control switch of the front panel of the equipment and switch on power supply.
I Put the workpiece into the induction coil and then step on the feet switch to start heating.
II Adjust the power control knob to make the heating speed achieve technics requirement.
III Loosen the feet switch after heating finish and then take out the workpiece.
IV Stop heating and close power supply switch and the air-break switch on the switchboard after all completed.
a Turnoff the cooling water after 10 minutes.
b
c
d
IV.Operation Precautions
1. Please ensure the casing connects to earth in accordance with the standard of electric work to prevent from electric shock.
2. Dismantle and installation of inductor must be done after stopping heating.
3. Firstly connect the equipment with water and then connect it with power. The inner of equipment and inductor must be cooled down with clean water to prevent the cooling pipe from blocking. If the equipment supplies water with pump, please install filter screen at pump intake. Temperature of cooling water shall not be higher than 37℃ with water flux 10T/h (It is better to use intenerated water), or else will lead to equipment alarm even overheating damage.
4. The equipment must be avoided insolation, drench, dampness and dust. Please carry the serving and maintenance after power off one hour.
5. Please make sure the induction coil is clean to avoid short circuit between the turns of inductors.
6. The equipment cannot use loop inductor, which will make inductive reactance too low and lead to damage of equipment. Under special circumstance, please consult with manufacturer.
7. The cooling water must be clean without impurity. It is prohibited to be short of water under work condition. Please set a filter at the entrance of suction stroke.
8. Descale the waterway of equipment with the detergent (we supply it) every four months. Please clean immediately when the alarm indicator lamp for water temperature is on frequently or water current from the out water gap is decreased patently.
9. Clean the inner of equipment: Blow it clean with compressed air or blowing machine. Clean the circuit board with brush and then blow it.
10. Inductor connect board must be polished with a sand paper to keep good electrical conductivity if you replace inductor.
V.Troubles and Settlements
Troubles |
Possible reasons |
Settlements |
No power indication |
1.Bad contact of power supply switch on the panel 2.1A protective tube broken 3.open-phase |
1. Close and open ,do several times 2.Change a new 1A protective tube 3.Check the power voltage |
Work lamp is not on after operating the feet switch |
1.Feet switch down-lead falls off 2.AC contactor pull-in failure or with bad contact 3.Inductor with bad contact |
Examine feet switch, AC contactor or inductor |
No current indication or little after turn the panel power to maximum |
1.Too many turns of inductor or too much load 2.Inductor with short circuit 3.Inductor with bad contact 4.Inner insert is loose or bolt is loose |
1.Change a new inductor 2.Restart 3.Polish joint or acid wash |
Workpiece cannot be heated after putting in |
1.The capacity of out power supply is too small or the line is too thin 2.Open-phase 3.Too many turns of inductor or too much load 4.Half bridge condition |
1.Increase power supply capacity 2.Examine three-phase power supply 3.Change a new inductor 4.Contact with manufacturer |
Over current alarm |
1.Inductor with bad contact or short circuit 2.AC contactor with bad contact 3.turns of inductor are overmany or less 4.there is spark at the joint of out power supply 5.High frequency cable with bad contact 6.power board is broken 7.there is spark in inner 8.Syntonic transformer is broken |
1.Examine inductor, high frequency cable and out power supply 2.Change a new AC contactor 3.Reduce turns of inductor 4.Examine power tube |
water pressure alarm |
1.Water press is too low 2.scale block 3.water press switch is broken |
1.increase water pressure 2.Cleanout the scale 3.Change a new switch |
water temperature alarm |
1.Water temperature is too high 2.water flux is too small 3.Water pipe jam 4.much scale 5.water temperature relay broken |
1.Change cooling water 2.Increase pump or water press 3.Use the detergent with proportion of 1:40 to clean 4.Change a new water temperature reply |
Over voltage alarm |
The over voltage indication lamp is on, which indicates voltage is higher than 420V. The machine stops working automatically. |
Deal with mains voltage |
Open-phase alarm |
lead-in power supply open-phase |
Check the lead-in power supply |
VI.Technical Parameters
Model |
WH-VI-16 |
WH-VI-26 |
WH-VIII-40 |
WH-VIII-50 |
WH-VIII-80 |
WH-VIII-120 |
WH-VIII-160 |
WH-B-260 |
Input power |
16KVA |
26KVA |
40KVA |
50KVA |
80KVA |
120KVA |
160KVA |
260KVA |
Input voltage |
Single-phase 220V 50-60HZ |
Three-phase 380V 50-60 HZ |
Three-phase 380V 50-60 HZ |
Three-phase 380V 50-60 HZ |
Three-phase 380V 50-60 HZ |
Three-phase 380V 50-60 HZ |
Three-phase 380V 50-60 HZ |
Three-phase 380V 50-60 HZ |
Oscillating frequency |
30-50KHZ |
30-50KHZ |
15-30KHZ |
15-30KHZ |
15-28KHZ |
15-25KHZ |
15-25KHZ |
15-20KHZ |
Infall hydraulic pressure |
≥0.05MPa |
≥0.05MPa |
≥0.05MPa |
≥0.05MPa |
≥0.05MPa |
≥0.0 |
VII.Circuit Principle Frame
控制单元:Control cell驱动单元:Drive cell
显示单元:Display cell 启动:Start 停止:Stop 电源:Power supply 工作:Work 过流:Over current 缺水:Lack water 过热:Over hot 过压:Over voltage 输出电流显示:Output currency display
VIII.Packing List of Equipment
1. Control tank, one set 2. A set of transformer tank (Separate) 3. Three inductors 4.Instruction book 5. Certificate of competency 6. Warranty card
推荐内容 Recommended
- 银行对账单翻译09-16
- 交通运输行业翻译_专业交通运输行09-16
- 留学学历认证翻译_国外学历认证翻09-15
- 高中毕业证翻译_大学本科毕业证翻09-15
- 【专业收入证明翻译_收入证明翻译09-15
- 在职证明翻译_签证在职证明英文09-15
- 意外险翻译_意外险合同翻译_意外险09-15
- 基因工程翻译_基因工程翻译公司09-15
- 【专业维修手册翻译_维修手册翻译09-15
- 经营许可证翻译_生产许可证翻译09-15
相关内容 Related
- 英国个人旅游签证、探亲访友和商09-13
- 英国留学签证流程及步骤09-13
- 英国签证材料的英文版还需要盖章09-13
- 为什么标点符号也要算翻译字数?09-12
- 为什么数字、字母也要算翻译字数09-12
- 翻译笔译资料字数是如何统计的09-12
- 【退休证翻译_退休证明英文翻译】09-12
- 英语标点符号的标准用法09-11
- 【亲属移民材料翻译,加拿大美国09-11
- 国外大学录取通知书offer翻译09-11